  130 kv microfocus x-ray source l9181-02 features applications [applicable objects] ?lectronic component ?rinted circuit board ?lastic component ?etal component  focal spot size: 5 m (at 4 w) the focal spot of 5 m of the sealed type x-ray tube offers sharp and clear x-ray images even at a high magnification.  no high voltage cable connection required high voltage power supply is integrated.  external control via rs-232c interface  high power: maximum output 39 w  non-destructive inspection  x-ray ct x-ray source
precautions to use this microfocus x-ray source generates x-rays harmful to the human body. use sufficient caution when handling the equipment to avoid direct or inadvertent exposure to x-rays. install the x-ray source or the x-ray tube unit in an x-ray shielded cabinet or room equipped with safety interlock functions t o prevent accidental exposure to x-rays. ! operational caution this microfocus x-ray source generates x-rays and must therefore be used only under the supervision of qualified personnel. this microfocus x-ray source shall be used in compliance with health and safety regulations enforced in order to prevent healt h hazards problems due to ionizing radiation. specifications general ratings 1 see the graph of the x-ray tube voltage / current operation range. 2 reference value: with 50 % of maximum x-ray emission. 3 this weight includes the accessories of approx. 0.25 kg. 4 the control software is provided as a sample software for the purpose of mfx operation. the performance of the software is not guaranteed. note: x-ray tube voltage setting range x-ray tube current setting range x-ray tube voltage operational range 1 x-ray tube current operational range 1 maximum output x-ray focal spot size (nominal value) x-ray output window material / thickness x-ray beam angle 2 focus to object distance (fod) terget material weight 3 communication method small focus mode middle focus mode large focus mode small focus mode middle focus mode large focus mode 0 to 130 0 to 300 40 to 130 10 to 300 8 16 39 8 (5 m at 4 w) 20 40 beryllium/0.2 approx. 45 approx. 13 tungsten approx. 10.5 interface: rs-232c (9-pin d-sub connector) kv a kv a w m mm degree mm kg description / value unit parameter input voltage (dc) power consumption read output operating ambient temperature storage ambient temperature operating and storage humidity +24 (+2.4, -0) less than 120 continuous rating +10 to +40 0 to +50 20 to 85 (no condensation) v w c c % description / value unit parameter regulation and standard rohs directive emc en 50581 category 9 description unit parameter control software 4 applicable pc applicable os interface pc / at compatible windows xp, 7 rs-232c interface description unit parameter iec/en 61326-1 emission limits: cispr 11 group 1 class a immunity requirements: table 2
x-ray tube voltage / current operation range dimensional outline (unit: mm) txpra0024ea txprb0024ea tube current ( a) tube voltage (kv) 40 60 80 100 120 130 350 300 250 200 150 100 50 0 middle focus mode small focus mode large focus mode * the x-ray tube voltage guaranteed range is 40 kv to 130 kv. * operation is not guaranteed when the tube current is below 10 a. power dc 24 v interlock-1 interlock-2 rs-232c 147.0 0.5 172 1 4 m6 depth 8 (mounting screw holes) * connection cables aren , t included. cooling fan x-ray focal spot fod 13 22.5 22.5 195 1 319 1 78 1 147.0 0.5 4.5 2 m3 depth 5 44 100 147.0 0.5 12 85 min. (reference)* 4 m6 depth 8 (mounting screw holes) protective earth terminal 9.5 167 1 147.0 0.5 86 1 147.0 0.5 x-ray focal spot 4 m6 depth 8 (mounting screw holes) 147.0 0.5 23 45 x-ray beam angle
txpr1015e02 nov. 2015 ip related products windows is a registered trademark of microsoft corporation in the united states and/or other countries. other product and software names mentioned herein may be either registered trademarks or trademarks of their respective owners. fos (fiber optic plate coated with x-ray scintillator)  structure the fos is an optical device for x-ray imaging, fabricated by coating an x-ray scintillator material over a fiber optic plate c onsisting of more than tens of million glass fibers each a few micrometers in diameter. the fos provides higher sensitivity and resolutio n than currently used sensitized paper films and also allows real-time digital radiography when directly coupled to a commerciall y available ccd. the fiber optic plate used in the fos has excellent x-ray absorption characteristics, so that x-rays penetrating the x-ray scintillator and directly entering the ccd are minimized to less than 1 %. this protects the ccd from the deterioration a nd in- creased noise caused by x-ray irradiation, assuring a long service life and maintaining high image quality. various sizes and shapes of fos are available to meet your particular needs, including tapered fop types. x-ray image intensifier digital camera unit c7336-05/-52 the c7336 series consist of a high resolution, high contrast 4-inch x-ray image in- tensifier (x-ray i.i.) and a 2.8 megapixel cmos image sensor. the x-ray i.i. used has a fixed field-of-view of 100 mm diameter or a 4 inches/2 in- ches adjustable field-of-view and an input window made of thin aluminum which is excellent in x-ray transmission and causes less scattering of x-rays. these features allow real-time detection at x-ray energy levels from about 20 kev. the captured images can be transferred to pc directly by interface of ieee1394b. x-cube (compact x-ray ccd camera) h8480, h8481, h8953 x-cubes are compact x-ray ccd camera designed for non-destructive inspection, which make x-ray imaging as easy as an ordinary ccd camera in handling. the h8480 and h8953 use a 2/3 type ccd coupled to large-diameter tapered fops which are coated with csi. the h8481 uses a straight type fop instead of the large fop, achieving a high resolution of 20 lp/mm. left: h8480 center: h8953 right: h8481 2d image-device protection film fop (fiber optic plate) scintillator : csi(tl) txprf0020 tmcpf0072 information furnished by hamamatsu is believed to be reliable. however, no responsibility is assumed for possible inaccuracies or omissions. specifications are subject to change without notice. no patent rights are granted to any of the circuits described herein. ?2015 hamamatsu photoni cs k.k. subject to local technical requirements and regulations, availability of products included in this promotional material may var y. please consult with our sales office. hamamatsu photonics k.k. hamamatsu photonics k.k., electron tube division 314-5, shimokanzo, iwata city, shizuoka pref., 438-0193, japan, telephone: (81)539/62-5248, fax: (81)539/62-2205 www.hamamatsu.com u.s.a.: hamamatsu corporation: 360 foothill road, bridgewater. n.j. 08807-0910, u.s.a., telephone: (1)908-231-0960, fax: (1)908-231-12 18 e-mail: usa@hamamatsu.com germany: hamamatsu photonics deutschland gmbh: arzbergerstr. 10, d-82211 herrsching am ammersee, germany, telephone: (49)8152-375-0, fa x: (49)8152-2658 e-mail: info@hamamatsu.de france: hamamatsu photonics france s.a.r.l.: 19, rue du saule trapu, parc du moulin de massy, 91882 massy cedex, france, telephone: (3 3)1 69 53 71 00, fax: (33)1 69 53 71 10 e-mail: infos@hamamatsu.fr united kingdom: hamamatsu photonics uk limited: 2 howard court, 10 tewin road, welwyn garden city, hertfordshire al7 1bw, united kingdom, tele phone: (44)1707-294888, fax: (44)1707-325777 e-mail: info@hamamatsu.co.uk north europe: hamamatsu photonics norden ab: torshamnsgatan 35 se-164 40 kista, sweden, telephone: (46)8-509-031-00, fax: (46)8-509-031-01 e -mail: info@hamamatsu.se italy: hamamatsu photonics italia s.r.l.: strada della moia, 1 int. 6, 20020 arese (milano), italy, telephone: (39)02-93581733, fax: (39)02-93581741 e-mail: info@hamamatsu.it china: hamamatsu photonics (china) co., ltd.: b1201 jiaming center, no.27 dongsanhuan beilu, chaoyang district, beijing 100020, china , telephone: (86)10-6586-6006, fax: (86)10-6586-2866 e-mail: hpc@hamamatsu.com.cn


▲Up To Search▲   

 
Price & Availability of L9181-02-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X